ASTM F1249 PDF

Water Vapor Transmission Rate (WVTR) ASTM F Permeation of Flexible Barrier Materials Using a Modulated Infrared Sensor. Water Vapor Transmission . Designation: F – 05 Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated. ASTM F outlines an instrumented procedure for determining the rate of water ASTM F is a standard test method for measuring the water vapor.

Author: Shaktir Zologis
Country: Guadeloupe
Language: English (Spanish)
Genre: Sex
Published (Last): 15 January 2005
Pages: 80
PDF File Size: 20.25 Mb
ePub File Size: 2.6 Mb
ISBN: 290-7-60383-151-2
Downloads: 32420
Price: Free* [*Free Regsitration Required]
Uploader: Kazrarn

The lowest detection limit is limited by the balance, usually only measures WVTR above 0. A superscript epsilon e indicates an editorial change since the last revision or reapproval.

The number of laboratories and materials in this study does not meet the minimum requirements for determining precision prescribed in Practice E Users of this standard are expressly advised that determination of the validity of any c1249 patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

These shall incorporate O—rings suitable for sealing the diffusion cell to the test chamber pneumatic? NOTE 1—Values for water vapor permeance and water vapor permeability must be used with caution. Again, this is necessary only in the earlier model WVTR f1294 that have a separate conditioning rack and testing chamber.

The inverse relationship of WVTR to thickness and the direct relationship of WVTR to the partial pressure differential of water vapor may not always apply. This information is then used to calculate the rate at which moisture is transmitted through the material being tested. In earlier model WVTR equipment, a separate desiccant drying system is needed for the conditioning rack and test chamber.

Asrm calculations are meaningful only in cases where materials have been determined to be homogeneous. These may be applied to both sides of a barrier to reduce the sample area. Last previous edition approved in as F — The dry chamber and the wet chamber make up a 1. F has many clear advantages over E96, including precision, repeatability, accuracy and sensitivity.

  BTA12 600C DATASHEET PDF

Water Vapor Transmission Rate (WVTR) ASTM F1249

The method is applicable to sheets and? It is desirable to thermostatically control the temperature of the conditioning rack as described in 6.

F can accurately differentiate barrier attributes of materials and packaging below the sensitivity limits of E Greater sensitivity provided by F methodology ensures lab and business managers have the information they need to make packaging decisions that meet requirements in challenging environmental conditions globally. Water vapor diffusing through the? ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

NOTE 3—When testing materials for which the operator has no previous history, additional time must be allowed to assure that true equilibrium has been reached.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Newer WVTR equipment does not require saturated salt solutions.

The test conditions see 3. Validating the specifications, value and safety of your raw materials, products and assets. For modern high barrier materials, this method is not sensitive enough to measure the results, or efficiently obtain results in a reasonable time period. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Reagents and F2149 7.

Water Vapor Transmission Rate (WVTR) ASTM F Standard – Labthink

Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

  DWARVEN QUEST FOR THE ROD OF SEVEN PARTS PDF

When in doubt, retest after an additional conditioning interval of f12449 hours. Work Item s – proposed revisions of this standard. Inspection Validating the specifications, value and safety of your raw materials, products and assets. Due to the limitation of the sensitivity.

Water Vapor Transmission Rate (WVTR) ASTM F

Test results from E96 method are also highly operator 1f249. Water Vapor Transmission Rate Scope: The test chamber shall incorporate means for clamping the diffusion cell in accurate registration with pneumatic system openings to the dry-air source and the infrared detector.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Key factors to understand material permeation include thickness of the material and environmental factors such as relative humidity and temperature.

The value of C is derived from tests of a known reference? The accuracy of this method is therefore dependent upon the validity of the values assigned to these reference?

Dry air is continually purging the dry chamber of those cells that are connected to the conditioning rack while the humid chamber side is held at a speci?

These entries should be rounded off to three signi? Needed only with certain WVTR instruments.

ASTM F1249

The permeability is meaningful only for homogeneous materials, in which case it is a property characteristic of bulk material. The chamber shall also provide a thermometer well for the measurement of temperature. A thermistor sensor and an appropriate control circuit will serve to regulate the temperature unless measurements are being made close to ambient temperature.